CUTLER HAMMER BUS PLUGS

CUTLER HAMMER P3BHKD3400GN


Bus Plug P3BHKD3400GN CUTLER HAMMER

Bus Plug P3BHKD3400GN CUTLER HAMMER


Actual Image May Vary

P3BHKD3400GN

CUTLER HAMMER

OR

Call 800-803-9256 for Pricing.


View more items in this category
All CUTLER HAMMER
All Manufacturers

P3BHKD3400GN

CUTLER HAMMER

OR

Call 800-803-9256 for Pricing.


View more items in this category
All CUTLER HAMMER
All Manufacturers

P3BHKD3400GN

CUTLER HAMMER

OR

Call 800-803-9256 for Pricing.


View more items in this category
All CUTLER HAMMER
All Manufacturers
Need Product Assistance?

Contact our "Rapid Fire" Technical Support at 800.803.9256

P3BHKD3400GN Specifications:

Model / Cat. No.: P3BHKD3400GN
Product: Bus Plug
Manufacturer: CUTLER HAMMER
Stock No.: 28-9070
Volts: 600
Amps: 400
Poles: 3
Description: Stock # 28-9070, CUTLER HAMMER, Bus Plug, Catalog No. P3BHKD3400GN, 600 Volts, 400 Amps, 3 Poles

Reconditioned Bug Plugs

The P3BHKD3400GN Bug Plug has been reconditioned per MIDWEST's rigorous service procedures based on 30 years experience.  The P3BHKD3400GN bug plug has been maintained and refurbished per industry standards and per MIDWEST's Quality Control Program (QCP).  The services include applicable internal and external procedures, repairs, and replacement of deficient components.  In addition to standard electrical tests, MIDWEST also performs live function tests on the P3BHKD3400GN.  These services far exceed the routine reconditioning of the P3BHKD3400GN performed by many bug plug vendors and resellers.  MIDWEST certifies the P3BHKD3400GN bug plug has passed our QCP before shipping.


New Surplus Bug Plugs

A "New Surplus" Bug Plug is a bug plug that has never been installed, but is not "New from the Factory" or "New from the Manufacturer or Distributor" of the P3BHKD3400GN bug plug.  It may be referred to as New in the Box, New Surplus, Never Installed, Never Energized, or other such term that avoids the label "New from the Manufacturer."  A New Surplus P3BHKD3400GN bug plug should not be considered new from the manufacturer or manufacturer's Distributor.  Surplus and New Surplus P3BHKD3400GN bug plugs must pass MIDWEST's (QCP) Quality Control Program.


Bus Duct and Bus Plug Basics

Electrical bus duct and bus plugs are an effective way to distribute power about a building that feeds many loads.  Visualize bus duct as a metal enclosure that might be 6" deep, 8" high, and 100 ft. to 600 ft. long, hanging from the ceiling of a large manufacturing building.  Inside the metal enclosure are copper or aluminum rods or bars that carry the current.  They might carry 600 amps to 4000 amps of power.  You may have looked right at a bus duct in a manufacturing plant and not really noticed it.  But it gets noticed by everyone very quickly if it is disturbed by something, say a platform lift, that results in a horrific arcing fireball.

Electrical bus duct is manufactured for three applications, (1) Service Bus Duct, (2) Feeder Bus Duct, and (3) Plug In Bus Duct.  The basic difference is that a bus plug or bus plugs are installed on Plug In Bus Duct only.  Service Bus Duct takes power from a source outside a building and carries it to a main electrical distribution center, switchboard, or panel board inside the building.  Feeder Bus Duct takes power from the main electrical distribution center inside the building and carries it to another large electrical distribution center further inside the building.  Both Service Bus Duct and Feeder Bus Duct take power from one point directly to another.  But Plug In Bus Duct is the real work horse.  Plug In Bus Duct has removable metal plates on its sides all along the length of the bus.  A plate is removed and a bus plug inserted into the side of the bus duct.  Many bus plugs can be inserted into a single bus duct.  Typically a bus plug is installed near a machine, or other load.  A conduit or cable assembly is dropped from the bus plug to the machine.  The bus plug is a protective power interrupting device.  It typically has a fused switch or circuit breaker inside.  It is sized for the load to be connected to the bus plug.  Plug In Bus Duct may have many bus plugs installed on it.  Plug In Bus Duct is a very effective way to distribute power in an area that has many machines and other loads and that may require frequent relocation of some machines.  It is a very simple task to remove and relocate a bus plug or even a group of bus plugs.

MIDWEST must advise following an extremely important "Safe Work Practice."  MIDWEST strongly recommends a "Safety Policy" of always turning off the power to the bus duct before removing or installing a bus plug.  We recommend this Safe Work Practice for the following reasons:

  1. Probably very high arc flash hazard levels,
  2. The electrician typically is very close to the probable source of the arc.  The electrician basically has to 'hug' the bus plug to remove or install it.
  3. The protective device for the bus duct may be sized for continuity of service instead of fast response to a fault.
  4. The protective device for the bus duct and in the bus plugs may be a circuit breaker.  Under a fault condition, breakers can be slow and fuses can be fast.  The fuse may be your friend.  The breaker your enemy.
  5. The electrician can not escape the hazard area.  He/she may actually fall into the arc source.
  6. The electrician typically is working at a dangerous elevation.


In manufacturing facilities, bus duct and bus plugs are common.  In most facilities the bus plug is switched from the floor, using an insulated 'hot' stick.  The bus plug operating handle would have an opening that permits inserting the stud at the end of the hot stick such that the handle can be pulled or pushed to safely turn the bus plug off and on.
To request other accessories for the

P3BHKD3400GN CUTLER HAMMER bus plug

, click here and fill in the email form.
View a complete list of CUTLER HAMMER bus plugs

Products Similar to P3BHKD3400GN



P3BHKD3300 - CUTLER HAMMER, Bus Plug, Catalog No. P3BHKD3300, 600 Volts, 300 Amps, 3 Poles,

P3BHKD3300G - CUTLER HAMMER, Bus Plug, Catalog No. P3BHKD3300G, 600 Volts, 300 Amps, 3 Poles,

P3BHKD3300GN - CUTLER HAMMER, Bus Plug, Catalog No. P3BHKD3300GN, 600 Volts, 300 Amps, 3 Poles,

P3BHKD3300N - CUTLER HAMMER, Bus Plug, Catalog No. P3BHKD3300N, 600 Volts, 300 Amps, 3 Poles,

P3BHKD3350 - CUTLER HAMMER, Bus Plug, Catalog No. P3BHKD3350, 600 Volts, 350 Amps, 3 Poles,

P3BHKD3400N - CUTLER HAMMER, Bus Plug, Catalog No. P3BHKD3400N, 600 Volts, 400 Amps, 3 Poles,

P3BHMC3500 - CUTLER HAMMER, Bus Plug, Catalog No. P3BHMC3500, 600 Volts, 500 Amps, 3 Poles,

P3BHMC3500N - CUTLER HAMMER, Bus Plug, Catalog No. P3BHMC3500N, 600 Volts, 500 Amps, 3 Poles,

P3BHMC3600 - CUTLER HAMMER, Bus Plug, Catalog No. P3BHMC3600, 600 Volts, 600 Amps, 3 Poles,

P3BHMC3600N - CUTLER HAMMER, Bus Plug, Catalog No. P3BHMC3600N, 600 Volts, 600 Amps, 3 Poles,


MIDWEST’s reconditioned, new, new surplus, and used bus plug inventory is changing constantly.  Frequently, bus plugs are sold even before they have been placed into MIDWEST's Web site inventory.  If you don’t see what you are looking for, please call 800.803.9256 or 414.461.8200 and speak to one of our Engineering Service Technicians for immediate help.

If you only need the bus plug for a short time, you may wish to consider renting a used or new surplus unit.

© 2024 MIDWEST Electrical Testing & Maintenance Co., Inc.
N93 W16170 Megal Drive · Menomonee Falls, WI 53051
Toll-Free: 800.803.9256 · Local: 414.461.8200 · Fax: 414.461.8485
We Accept Credit Cards
Accept Credit Cards









Recently Viewed Items
X Close
IMMEDIATE HELP!

Enter your Name and Phone Number and we will call you immediately.
Enter your Name and Phone Number or Email Address and we will contact you immediately.



Name:
Phone No.:
E-Mail:
Message:
(Optional)
Request Support
Thank your for your inquiry. Our Technical Support Team will contact you soon.
Click the HELP button for an immediate call from MIDWEST's Electrical Experts.

Available Monday - Friday
7 AM - 4:30 PM Central Time