DA-50 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DA-50, Frame Amps 1600, Trip Amps 800, DASHPOT Trip Device, MO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DA-50 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DA-50, Frame Amps 1600, Trip Amps 1200, DASHPOT Trip Device, MO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DA-50 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DA-50, Frame Amps 1600, Trip Amps 1600, DASHPOT Trip Device, MO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DA-50 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DA-50, Frame Amps 1600, Trip Amps 1600, DASHPOT Trip Device, MO,DO EO/DO Operation, NA Close Volts, 125 VDC Shunt Volts, |
DA-50 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DA-50, Frame Amps 1600, Trip Amps 400, DASHPOT Trip Device, MO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DA-50 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DA-50, Frame Amps 1600, Trip Amps 600, DASHPOT Trip Device, MO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DA-75 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DA-75, Frame Amps 3000, Trip Amps , DASHPOT Trip Device, EO/DO EO/DO Operation, 125VDC Close Volts, 125VDC Shunt Volts, |
DA-75 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DA-75, Frame Amps 3000, Trip Amps 3000, DASHPOTS Trip Device, MO,BOLT-IN EO/DO Operation, NA Close Volts, 120 VAC Shunt Volts, |
DB-25 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DB-25, Frame Amps 600, Trip Amps 500, DASHPOT Trip Device, MO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DB-25 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DB-25, Frame Amps 600, Trip Amps 400, DASHPOT Trip Device, MO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DB-25 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DB-25, Frame Amps 600, Trip Amps 300, DASHPOT Trip Device, MO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DB-25 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DB-25, Frame Amps 600, Trip Amps 600, STATIC II Trip Device, MO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DB-25 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DB-25, Frame Amps 600, Trip Amps 600, DIGITRIP RMS R500 Trip Device, MO/DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DB-25 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DB-25, Frame Amps 600, Trip Amps 600, DASHPOT Trip Device, MO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DB-25 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DB-25, Frame Amps 600, Trip Amps 300, DASHPOT Trip Device, EO,DO EO/DO Operation, 125 VDC Close Volts, 125 VDC Shunt Volts, |
DB-25 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DB-25, Frame Amps 600, Trip Amps 0, AMPTECTOR Trip Device, MO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DB-25 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DB-25, Frame Amps 600, Trip Amps 225, DASHPOT Trip Device, MO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DB-25 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DB-25, Frame Amps 600, Trip Amps 100, DASHPOT Trip Device, MO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DB-25 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DB-25, Frame Amps 600, Trip Amps , DASHPOT Trip Device, MO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DB-25 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DB-25, Frame Amps 600, Trip Amps 200, DASHPOT Trip Device, MO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DB-50 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DB-50, Frame Amps 1600, Trip Amps 1200, AMPTECTOR Trip Device, MO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DB-50 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DB-50, Frame Amps 1600, Trip Amps 1200, AMPTECTOR 1A Trip Device, MO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DB-50 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DB-50, Frame Amps 1600, Trip Amps 1000, DASHPOT Trip Device, MO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DB-50 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DB-50, Frame Amps 1600, Trip Amps 1000, DASHPOT Trip Device, MO.BOLT-IN EO/DO Operation, NA Close Volts, Shunt Volts, |
DB-50 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DB-50, Frame Amps 1600, Trip Amps 1600, DASHPOT Trip Device, EO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DB-50 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DB-50, Frame Amps 1600, Trip Amps 1600, STATIC II Trip Device, MO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DB-50 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DB-50, Frame Amps 1600, Trip Amps 1200, DASHPOT Trip Device, MO,BOLT-IN EO/DO Operation, NA Close Volts, Shunt Volts, |
DB-50 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DB-50, Frame Amps 1600, Trip Amps 1200, DASHPOT Trip Device, MO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DB-50 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DB-50, Frame Amps 1600, Trip Amps 0, NO TRIPS Trip Device, MO, DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DB-50 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DB-50, Frame Amps 1600, Trip Amps 400, AMPTECTOR Trip Device, MO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DB-50 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DB-50, Frame Amps 1600, Trip Amps 1600, DASHPOT Trip Device, MO.BOLT-IN EO/DO Operation, NA Close Volts, Shunt Volts, |
DB-50 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DB-50, Frame Amps 1600, Trip Amps 1600, AC-PRO Trip Device, MO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DB-50 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DB-50, Frame Amps 1600, Trip Amps 600, DASHPOT Trip Device, MO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DB-50 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DB-50, Frame Amps 1600, Trip Amps 800, DASHPOT Trip Device, MO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DB-50 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DB-50, Frame Amps 1600, Trip Amps 400, DASHPOT Trip Device, MO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DB-50 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DB-50, Frame Amps 1600, Trip Amps 600, AMPTECTOR Trip Device, MO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DB-75 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DB-75, Frame Amps 3000, Trip Amps 3000, DASHPOT Trip Device, EO,DO EO/DO Operation, 220 VAC Close Volts, 0 Shunt Volts, |
DB-75 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DB-75, Frame Amps 3000, Trip Amps 3000, DASHPOTS Trip Device, EO,BOLT-IN EO/DO Operation, 125 VDC Close Volts, 220 VDC Shunt Volts, |
DB-75 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DB-75, Frame Amps 3000, Trip Amps 2500, AMPTECTOR Trip Device, EO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DB-75 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DB-75, Frame Amps 3000, Trip Amps 2000, FACTORY TRIPS Trip Device, EO,DO EO/DO Operation, 220 Close Volts, 48VDC 110V Shunt Volts, |
DBF-6 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DBF-6, Frame Amps 600, Trip Amps 0, Trip Device, EO,DO EO/DO Operation, 250 VDC Close Volts, ? Shunt Volts, |
DBL-25 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DBL-25, Frame Amps 600, Trip Amps 400, DASHPOT Trip Device, MO,DO EO/DO Operation, NA Close Volts, 48 VDC Shunt Volts, |
DBL-25 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DBL-25, Frame Amps 600, Trip Amps 400, DASHPOT Trip Device, MO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DK-15 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DK-15, Frame Amps 225, Trip Amps 225, DASHPOT Trip Device, MO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DK-25 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DK-25, Frame Amps 600, Trip Amps 400, DASHPOT Trip Device, MO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DK-25 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DK-25, Frame Amps 600, Trip Amps , DASHPOT Trip Device, MO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DK-25 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DK-25, Frame Amps 600, Trip Amps 600, DASHPOT Trip Device, MO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DS206 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DS206, Frame Amps 800, Trip Amps 400, AMPTECTOR 1A Trip Device, MO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DS206 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DS206, Frame Amps 800, Trip Amps 800, AMPTECTOR IIA Trip Device, EO/DO EO/DO Operation, 120 VAC Close Volts, 24 VDC Shunt Volts, |
DS-3200 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DS-3200, Frame Amps 3200, Trip Amps 0, FUSES Trip Device, MO,DO EO/DO Operation, Close Volts, Shunt Volts, |
DS416 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DS416, Frame Amps 1600, Trip Amps 1600, Trip Device, MO,DO EO/DO Operation, Close Volts, Shunt Volts, |
DS416 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DS416, Frame Amps 1600, Trip Amps 1200, AMPTECTOR IIA MODEL TR Trip Device, MO/DO EO/DO Operation, Close Volts, Shunt Volts, |
DS-416 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DS-416, Frame Amps 1600, Trip Amps 1600, AMPTECTOR 1-A Trip Device, MO,DO EO/DO Operation, Close Volts, Shunt Volts, |
DS420 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DS420, Frame Amps 2000, Trip Amps 800, AMPTECTOR I-A Trip Device, MO/DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DS420 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DS420, Frame Amps 2000, Trip Amps 2000, AMPTECTOR I-A Trip Device, MO/DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DS420 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DS420, Frame Amps 2000, Trip Amps 800, AMPTECTOR 1A Trip Device, MO/DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DS420 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DS420, Frame Amps 2000, Trip Amps 400, AMPTECTOR 1A Trip Device, MO/DO EO/DO Operation, Close Volts, Shunt Volts, |
DS420 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DS420, Frame Amps 2000, Trip Amps 600, Trip Device, MO/DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DS420 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DS420, Frame Amps 2000, Trip Amps 600, AMPTECTOR Trip Device, MO/DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DS420 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DS420, Frame Amps 2000, Trip Amps 600, AMPTECTOR 1A Trip Device, MO/DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DS632 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DS632, Frame Amps 3200, Trip Amps 2400, AMPTECTOR 1 Trip Device, MO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DS-632 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DS-632, Frame Amps 3200, Trip Amps , AMPTECTOR 1A Trip Device, MO/DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DS840 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DS840, Frame Amps 4000, Trip Amps 4000, AMPTECTOR 1A Trip Device, EO/DO EO/DO Operation, 115 VAC Close Volts, 115 VAC Shunt Volts, |
DSL-206 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DSL-206, Frame Amps 800, Trip Amps 200, AMPTECTOR 1-A Trip Device, MO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
DSL-416 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DSL-416, Frame Amps 1600, Trip Amps 1600, AMPTECTOR Trip Device, MO,DO EO/DO Operation, NA Close Volts, 120 VAC Shunt Volts, |
DSL-416 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. DSL-416, Frame Amps 1600, Trip Amps 1600, AMPTECTOR Trip Device, EO,DO EO/DO Operation, 120 VAC Close Volts, 120 VAC Shunt Volts, |
SPB-100 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. SPB-100, Frame Amps 800, Trip Amps 300, POW-R-TRIP 7 Trip Device, MO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
SPB-100 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. SPB-100, Frame Amps 3000, Trip Amps 3000, POW-R-DIGITRIP Trip Device, EO,BOLT-IN EO/DO Operation, 120 VAC Close Volts, 120 VAC Shunt Volts, |
SPB-100 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. SPB-100, Frame Amps 2000, Trip Amps 0, NONE Trip Device, MO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
SPB-100 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. SPB-100, Frame Amps 800, Trip Amps 500, POW-R-TRIP 7 Trip Device, MO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |
SPB-50 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. SPB-50, Frame Amps 1600, Trip Amps 0, POW-R-TRIP 7 Trip Device, EO,DO EO/DO Operation, 0 Close Volts, 0 Shunt Volts, |
SPB-65 WESTINGHOUSE, Low Voltage Air Circuit Breaker, Catalog No. SPB-65, Frame Amps 1600, Trip Amps 1600, POW-R-TRIP 7 Trip Device, MO,DO EO/DO Operation, NA Close Volts, Shunt Volts, |